Continuous Emission Monitoring System(Ultra-low)

Model No.:JM-4200

The continuous emission monitoring system(Ultra-low) is suitable for monitoring the continuous exhaust gas emissions of various boilers. It adopts the direct extraction method to continuously monitor the concentration of particulate matter, sulfur dioxide (SO2) concentration, nitrogen oxide (NOx) concentration, oxygen (O2) content, measurement of parameters such as flue gas temperature, flue gas pressure, and flue gas flow rate. It can be connected to the computer of the higher-level environmental protection department through the network, and the environmental protection department can easily and quickly call monitoring data.

Inquiry

Detailed Description

1.Product overview:

The continuous emission monitoring system(Ultra-low) is suitable for monitoring the continuous exhaust gas emissions of various boilers. It adopts the direct extraction method to continuously monitor the concentration of particulate matter, sulfur dioxide (SO2) concentration, nitrogen oxide (NOx) concentration, oxygen (O2) content, measurement of parameters such as flue gas temperature, flue gas pressure, and flue gas flow rate. It can be connected to the computer of the higher-level environmental protection department through the network, and the environmental protection department can easily and quickly call monitoring data.

2.System composition

  • Continuous monitoring system for smoke composition
  • Particle concentration detection system
  • Traffic detection system
  • DAS system

3.Technical characteristics

  • High measurement accuracy of the system;
  • Using UV differential technology to measure SO2 and NO without being affected by other interfering gases such as water vapor;
  • The measurement results are not affected by fluctuations or attenuation of light source energy;
  • The measurement principle ensures that the zero point of the instrument has basically no drift;
  • Adopting German original imported condensers and adopting unique phosphoric acid addition technology, the loss of SO2 is avoided;
  • Adopting PLC control, with high degree of automation and low maintenance workload;
  • Modular system structure design, flexible configuration;
  • Strong anti-interference performance of the system;
  • The system is easy to operate and maintain;
  • High accuracy of system data collection;
  • Low monitoring lower limit, suitable for online monitoring of ultra-low emission gaseous pollutants.

4.Technical parameters of analytical instruments

  • Measurement range: SO2: 0-20-200 μ mol/mol;
  • NOx: 0-20-200 μ mol/mol (optional, customizable);
  • O2: 0-25%;
  • Accuracy: ≤ ± 1% F S;
  • Stability: Zero drift ≤ ± 1% F S/7d;
  • Range drift ≤ ± 1% F S/7d;
  • Sample gas flow rate: 1.5L/min ± 0.5L/min;
  • Response time: T90 ≤ 20 seconds (when gas passes directly through the chamber);
  • Chamber pressure: ≤ 20Kpa;
  • Contact capacity: 120VAC, 1A 24VDC, 1A;
  • Output signal: 4-20mA or 0-10mA DC optional;
  • Preheating time: ≤ 30min
  • Working environment: Temperature: -5 ℃~+45 ℃;
  • Humidity: ≤ 90% RH;
  • Working power supply: 220VAC ± 10%, 50Hz ± 5%.

5.Product parameters

Parameters Measuring method Measuring range Zero drift Span Drift Linear error Output signal
SO2 DOAS 0~20~200 μmol/mol ±1%FS/7d ±1%FS/7d ≤±1%FS RS-232/485,4~20mA
NOx DOAS 0~20~200 μmol/mol ±1%FS/7d ±1%FS/7d RS-232/485,4~20mA
CO Non dispersed infrared absorption method 0~2000 μmol/mol ±1%FS/7d ±1%FS/7d RS-232/485,4~20mA
O2 Electrochemical or magnetic pressure type 0~25% ±1%FS/7d ±1%FS/7d RS-232/485,4~20mA
Particulate matter(Dust) Laser forward scattering method 0~5~200mg/m3 ±2%FS/7d ±2%FS/7d ≤±3%FS 4~20mA
Current velocity Differential pressure sensing method 0~40m/S ±5%FS/7d ±5%FS/7d ≤±1%FS 4~20mA
Pressure Differential pressure sensing method 60~140KPa ±2%FS/7d ±2%FS/7d ≤±1%FS 4~20mA
Temperature thermocouple 0~500℃ ±1%FS/7d ±1%FS/7d ≤±1%FS 4~20mA
Humidity Capacitance method 0~100% ±2%FS/7d ±2%FS/7d ≤±1.5%FS 4~20mA

CONTACT US TODAY!

ADD.: Road no 23-1,Pingtung city,Taiwan.

Email: sales01@jinmietw.com

Contact No.:00886-0975665338

 

 

  • About us
  • Wastewater Monitoring Instrument
  • Flue Gas Monitoring Instrument
  • News
  • Contact us
©Copyright-2025-Jinmie Enterprise Co., ltd.All rights reserved.
  • About us
  • Wastewater Monitoring Instrument
  • Flue Gas Monitoring Instrument
  • News
  • Contact us
Scroll to top Scroll to top Scroll to top